Parameter Check
NOTE:
The parameter data registered in the VDCCM is shown on the display.
- Connect the Subaru Select Monitor.
- On «Start» display, select «Diagnosis».
- On «Vehicle selection» display, input the vehicle information and select «Confirmed».
- On «Main Menu» display, select «Each System».
- On «Select System» display, select «Brake Control System».
- On «Select Function» display, select «Work Support».
- On «Work Support» display, select «Confirm on parameter».
- On the «Confirm on parameter» display screen, check that the applied model and grade of the target vehicle are included, and click the [OK] button.
- If the applied model and grade of the target vehicle are not included on the «Confirm on parameter» display screen, perform "parameter selection and registration". Ref. to PARAMETER SELECTION , OPERATION, Subaru Select Monitor.