Execution Condition
| Secondary Parameters | Execution condition | |
|---|---|---|
| Battery voltage | ≥ 10.9 V | |
| Barometric pressure | > 75.1 kPa (563 mmHg, 22.2 inHg) | |
| Intake air amount | ≥ 6 g/s (0.21 oz/s) | |
| Rear oxygen sensor sub feedback | Execution | |
| Rear oxygen sensor output voltage - Feedback target voltage | -0.2 V - 0.1 V | |
| or | ||
| Rear oxygen sensor sub feedback compensation coefficient | On Min. | |
| or | ||
| Rear oxygen sensor sub feedback compensation coefficient | On Max. | |