Diagnostic Method
| Mode | Explanation of Mode | Diagnosis Period |
|---|---|---|
| A | Vacuum pump operation confirmation and characteristics stability | 7 s or less & 300 s |
| B | Measurement of reference pressure for setting the target negative pressure | 40 s or less |
| C | Switching valve operation confirmation | 12 s or less |
| D | Clogging of pipe diagnosis and leak pressure measurement | 900 s or less |
| D2 | Pipe clogging of the high pressure line Solenoid valve for secondary purge stuck closed | 60s |
| E | Reference pressure measurement for judgment | 40 s or less |
Mode A (Vacuum pump operation confirmation and characteristics stability)
Purpose: Detect the vacuum pump operation trouble.
Judge as NG when the following conditions are established.
Judge as OK if the following conditions are not established, and warm up for five minutes to stabilize the vacuum pump characteristics.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure sensor output value | > -224 Pa (-1.68 mmHg, -0.1 inHg) | P2404 |
Mode B (Measurement of reference pressure for setting the target negative pressure)
- Purpose: Judge the reference pressure stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONMalfunction Criteria Threshold Value DTC |Pressure sensor maximum output value - Pressure sensor minimum output value| > 314 Pa (2.355 mmHg, 0.1 inHg) P2404 - Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONMalfunction Criteria Threshold Value DTC Reference pressure for setting the target negative pressure < Value of Map 2 P2404 or > Value of Map 3 BAROMETRIC PRESSURE SPECIFICATION - MAP 2Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100(750, 29.5) Reference pressure for setting the target negative pressure kPa (mmHg, inHg) -4 (-29.79, -1.2) -4.1 (-30.593, -1.2) -4.2 (-31.395, -1.2) -4.3 (-32.19, -1.3) BAROMETRIC PRESSURE SPECIFICATION - MAP 3Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for setting the target negative pressure kPa (mmHg, inHg) -0.9 (-7.065, -0.3) -1 (-7.86, -0.3) -1.2 (-8.663, -0.3) -1.3 (-9.465, -0.4)
Mode C (Switching valve operation confirmation)
Purpose: Measure the pressure increase when switching valve is changed from open to close, and detect the stuck to open/close malfunctions of the switching valve.
Judge as NG when the following conditions are established.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure sensor output value - Reference pressure for setting the target negative pressure | < 224 Pa (1.68 mmHg, 0.1 inHg) | P2404 |
Mode D (Clogging of pipe diagnosis and leak pressure measurement)
- Clogging of pipe
Purpose: Measure the time required for the evaporative emission system to reach the target negative pressure by the vacuum pump, and detect the clogging of pipe trouble.
Judge as clogging of pipe malfunction if the evaporative emission system reaches to the target negative pressure within the specified time.
- Leak pressure measurement
Purpose: Measure the pressure (leak pressure) when the evaporative emission system becomes the negative pressure by the vacuum pump.
Store the pressure as a leak pressure while the following conditions are met.
| Conditions for storing the leak pressure | Threshold Value |
|---|---|
| When any one of the followings is established: | |
|
≥ Value of Map 4 |
|
< -5 kPa (-37.298 mmHg, -1.5 inHg) |
|
≥ 900000 ms |
Phase D2
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Phase D | ≤ 27000 ms | P1451 |
| or | ||
| Phase D2 | < -0.7 kPa (-5 mmHg, -0.2 inHg) |
Time Needed for Diagnosis: 24 min
Mode E (Measurement of reference pressure for judgment)
- Purpose: Judge the reference pressure stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONMalfunction Criteria Threshold Value DTC |Pressure sensor maximum output value - Pressure sensor minimum output value| > 314 Pa (2.355 mmHg, 0.1 inHg) P2404 - Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions.
Judge the vacuum pump performance stability. Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONMalfunction Criteria Threshold Value DTC Reference pressure for judgment < Value of Map 4 P2404 or >Value of Map 5 BAROMETRIC PRESSURE SPECIFICATION - MAP 4Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -4.5 (-34.02, -1.3) -4.6 (-34.815, -1.4) -4.7 (-35.618, -1.4) -4.9 (-36.42, -1.4) BAROMETRIC PRESSURE SPECIFICATION - MAP 5Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -0.8 (-6.18, -0.2) -0.9 (-6.983, -0.3) -1 (-7.785, -0.3) -1.1 (-8.58, -0.3) - Purpose: Judge the presence of evaporative emission system leak.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONMalfunction Criteria Threshold Value DTC < Large leak (0.04 inch) > P0455 Leak pressure ≥ Map6 (Pa) lleakjdg = (Reference pressure for judgment) X 0.377 - (-45.5 Pa) < Very small leak (0.02 inch) > P0456 Leak pressure < Map6 (Pa) VALUE SPECIFICATION - MAP 6Reference pressure (Pa) -4856 -4000 -2750 -1500 -824 Threshold Value (Pa) -1785 -1463 -991 -520 -265
Formula for threshold value = Reference pressure X 0.377 - -0.341 mmHg
Time Needed for Diagnosis: Approx. 24 min
At next engine start, confirm whether the enable conditions are satisfied even though refueling has been done during soaking, and determine the malfunction.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.