Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| ELCM pressure | > 666.6 Pa X -1 (5 mmHg X -1, 0.2 inHg X -1) |
Time Needed for Diagnosis: 30000 ms - 10000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.