Starting/Charging Systems (H4DO): Generator: Inspection: Diode
CAUTION:
There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
- Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.
| Tester lead |
Continuity |
| -lead |
+lead |
| E |
P1, P2, P3, P4, P5, P6 |
[Yes] |
| B |
None |
| P1, P2, P3, P4, P5, P6 |
E |
None |
| B |
[Yes] |
| Tester lead |
Continuity |
| -lead |
+lead |
| E |
P1, P2, P3, P4, P5, P6 |
None |
| B |
[Yes] |
| P1, P2, P3, P4, P5, P6 |
E |
[Yes] |
| B |
None |
Courtesy of SUBARU OF AMERICA, INC.