LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2016 >> Forester 2.5i, Eng CD FB25BA, Standard Trans >> Repair and Diagnosis >> Electrical >> Starting/Charging Systems (H4DO) >> Generator >> Inspection >> Diode

Starting/Charging Systems (H4DO): Generator: Inspection: Diode

CAUTION: There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
  1. Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.
Tester lead Continuity
-lead +lead
E P1, P2, P3, P4, P5, P6 [Yes]
B None
P1, P2, P3, P4, P5, P6 E None
B [Yes]
Tester lead Continuity
-lead +lead
E P1, P2, P3, P4, P5, P6 None
B [Yes]
P1, P2, P3, P4, P5, P6 E [Yes]
B None
Fig 1: Checking Continuity Between Diode Lead And Terminal E Or B
G07665194Courtesy of SUBARU OF AMERICA, INC.