LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2016 >> Forester 2.5i, Eng CD FB25BA, Standard Trans >> Repair and Diagnosis >> Electrical >> Starting/Charging Systems (H4DO) >> General Description >> Specification

Starting/Charging Systems (H4DO): General Description: Specification

Item Specifications
Vehicle model Non-turbo model Turbo model
CVT MT
Starter Type Reduction type
Model M000T38571 M000T33176 M000T20176
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.2 kW 12 V - 1.0 kW 12 V - 1.4 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 9 8 9
No-load characteristics Voltage 11 V
Current 90 A or less 95 A or less 90 A or less
Rotating speed 2, 370 r/minor more 2, 500 r/minor more 2, 000 r/minor more
Load characteristics Voltage 7.5 V 7.5 V 7.7 V
Current 300 A 300 A 400 A
Torque 10.65 N.m (1.1 kgf-m, 7.8 ft-lb) or more 8.84 N.m (0.9 kgf-m, 6.5 ft-lb) or more 16.7 N.m (1.7 kgf-m, 12.3 ft-lb) or more
Rotating speed 840 r/min or more 870 r/min or more 710 r/min or more
Lock characteristics Voltage 4 V 4 V 3.5 V
Current 780 A or less 680 A or less 960 A or less
Torque 20 N.m (2.0 kgf-m, 14.8 ft-lb) or more 17 N.m (1.7 kgf-m, 12.5 ft-lb) or more 31 N.m (3.2 kgf-m, 22.9 ft-lb) or more
Generator Type Rotating-field three-phase type, voltage regulator built-in type, with load response control system
Model A2TX3381
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 130 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase Δ type
Output current 1, 500 r/min - 50 A or more
2, 500 r/min - 111 A or more
5, 000 r/min - 133 A or more
  Regulated voltage 14.1 - 14.8 V [20°C (68°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Brush length Standard 22.5 mm (0.886 in)
Limit 5.0 mm (0.197 in)
Battery Type and capacity 12 V - 48 AH (55D 23L)
CCA 390 A