Check Motor
- Connect the battery positive terminal to terminal No. 2 and the battery ground terminal to terminal No. 1, and check that the valve is fully opened on LH side and the valve is fully closed on RH side.CAUTION: Do not power the motor for more than 10 seconds.
- Connect the battery positive terminal to terminal No. 1 and the battery ground terminal to terminal No. 2, and check that the valve is fully closed on LH side and the valve is fully opened on RH side.CAUTION: Do not power the motor for more than 10 seconds.