Check Clock System Communication Circuit
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK POWER SUPPLY.
|
Is the voltage 10 V or more? | Go to step 2. | Repair or replace the harness. |
| 2 CHECK GROUND CIRCUIT. Measure the resistance between MFD connector and chassis ground. Connector & terminal (i122) No. 2 - Chassis ground: |
Is the resistance less than 10 Ω? | Go to step 3. | Repair or replace the harness. |
3 CHECK MFD.
|
Is the MFD normal? | Repair the poor contact of connector. | Replace the MFD. |