Unit Inspection
- Ignition/starter switch assembly check
- Measure the resistance between connector terminals.
Resistance
Inspection terminals Inspection conditions Standard value - LOCK 10 k Ωor more 2 (AM1) - 3 (ACC) ACC Less than 1 Ω 2 (AM1) - 3 (ACC) - 4 (IG1) ON Less than 1 Ω 6 (IG2) - 7 (AM2) 1 (ST1) - 2 (AM1) - 4 (IG1) START Less than 1 Ω 6 (IG2) - 7 (AM2) - 8 (ST2)
- Measure the resistance between connector terminals.