LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2015 >> WRX STI >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Engine Cooling System (Except STI)) >> General Description >> Specification

Section 1 (Engine Cooling System (Except STI)): General Description: Specification

WARNING: This page is about a different variant/trim than selected.
Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity L (US qt, Imp qt) CVT model: Approx. 8.4 (8.9, 7.4)
MT model: Approx. 8.2 (8.7, 7.2)
Water pump Type Centrifugal impeller type
Discharge performance Discharge rate L (US gal, Imp gal)/min 248 (65.5, 54.6)
Pump speed - Discharge pressure 8, 580 rpm - 88 kPa (9.2 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 56 (2.2)
Number of impeller vanes 7
Pump pulley diameter mm (in) 100 (3.9)
Thermostat Type Wax pellet type
Starting temperature to open 86 - 90°C (187 - 194°F)
Fully opens 95°C (203°F)
Valve lift mm (in) 8.0 (0.315) or more
Valve opening size mm (in) 32 (1.26)
Radiator fan Motor input Main fan W 120
Sub fan W 120
Fan diameter/Blade Main fan 318.5 mm (12.54 in)/9
Sub fan 318.5 mm (12.54 in)/11
Radiator Type Down flow, pressure type
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 27 (27.06 x 13.39 x 1.06)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Positive pressure side Standard 93 - 123 (0.95 - 1.25, 14 - 18)
Limit 83 (0.85, 12)
Negative pressure side Standard -1.0 to -4.9 or less (-0.01 - -0.05, -0.1 - -0.7)
Fins Corrugated fin type
Reservoir tank Capacity L (US qt, Imp qt) 0.45 (0.48, 0.40)
  Recommended materials Item number Alternative
Coolant SUBARU SUPER COOLANT (concentrated type) - -
SUBARU SUPER COOLANT (diluted type) K0670Y0001
Water for dilution Distilled water - Soft water or tap water
Cooling system protective agent Cooling system conditioner SOA345001 -