Enable Conditions
Diagnostic method 1 and 2
ENGINE SPEED SPECIFICATION
| Secondary Parameters | Enable Conditions |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Closed loop control with main feedback (3000 ms or more) | Operation |
| Engine speed | ≥ 1000 rpm |
| Amount of intake air | ≥ 10 g/s (0.35 oz/s) |
Diagnostic method 3
VEHICLE SPEED SPECIFICATION
| Secondary Parameters | Enable Conditions |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Closed loop control with main feedback | Operation |
| Vehicle speed | > 40 km/h (24.9 MPH) |
| Engine speed | ≥ 1000 rpm and < 4000 rpm |
| Amount of intake air | ≥ 10 g/s (0.35 oz/s) and < 40 g/s (1.41 oz/s) |
| Catalyst depletion diagnosis | Not under diagnosis |