LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2015 >> WRX Premium, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 192 (Power Rear Gate (Diagnostics)) >> Control Module I/O Signal >> Electrical Specification >> Power Rear Gate Control Module

Power Rear Gate Control Module

WARNING: This page is about a different car, the 2016 Subaru Outback, 2016 Subaru Legacy, 2015 Subaru Outback, and 2015 Subaru Legacy. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Power Rear Gate Control Module I/O Signal Connector Terminal Identification
G10310000Courtesy of SUBARU OF AMERICA, INC.
Terminal No. Description Measuring condition Standard
(R422) No. 1 ←→ (R422) No. 9 Touch sensor When sensor is ON 2.7 V or less
(R422) No. 2 ←→ Chassis ground - - -
(R422) No. 3 ←→ (R422) No. 9 Latch switch When rear gate is fully closed 9 - 16 V
(R422) No. 4 ←→ (R422) No. 9 Courtesy switch When rear gate is fully closed 9 - 16 V
(R422) No. 5 ←→ (R422) No. 9 Sector switch When rear gate is fully closed Less than 1 V
(R422) No. 6 ←→ (R422) No. 9 PRG inner SW When power rear gate inner switch is ON Less than 1 V
(R422) No. 7 - - -
(R422) No. 8 ←→ Chassis ground Memory height switch When memory height switch is ON Less than 1 V
(R422) No. 9 Switch GND - -
(R422) No. 10 LIN communication line - -
(R422) No. 11 - - -
(R422) No. 12 ←→ Chassis ground Ignition SW When ignition switch is ON -
(R422) No. 13 ←→ Chassis ground Power rear gate driver's switch When driver's switch is ON Less than 1 V
(R422) No. 14 ←→ Chassis ground - - -
(R422) No. 15 ←→ Chassis ground Hazard output When hazard is not operating Less than 1 V
(R422) No. 16 ←→ Chassis ground - - -
(R423) No. 1 ←→ Chassis ground Battery power supply (+POWER B) Always 9 - 16 V
(R423) No. 2 ←→ Chassis ground Closer (CLOSE) When the power rear gate auto closer is performing the pull-in operation 9 - 16 V
(R423) No. 3 ←→ Chassis ground Closer (OPEN) When power rear gate auto closer is performing the release operation 9 - 16 V
(R423) No. 4 ←→ Chassis ground GND Always Less than 1 Ω
(R423) No. 5 ←→ Chassis ground - - -
(R423) No. 6 ←→ Chassis ground Battery power supply (+B) Always 9 - 16 V
(R424) No. 1 ←→ Chassis ground - - -
(R424) No. 2 ←→ Chassis ground - - -
(R424) No. 3 ←→ Chassis ground Motor (CLOSE) When auto-closing is in operation Pulse
(R424) No. 4 ←→ Chassis ground Motor (OPEN) When auto-open is in operation Pulse
(R424) No. 5 Buzzer (-) - -
(R424) No. 6 ←→ (R424) No. 5 Buzzer (+) When buzzer sounds Pulse
(R424) No. 7 ←→ Chassis ground - - -
(R424) No. 8 ←→ Chassis ground HALL RETURN - -
(R424) No. 9 ←→ (R424) No. 8 HALL2 - -
(R424) No. 10 ←→ (R424) No. 8 HALL1 - -
(R424) No. 11 ←→ Chassis ground HALL FEED - -
(R424) No. 12 ←→ Chassis ground - - -
(R424) No. 13 ←→ Chassis ground - - -
(R424) No. 14 ←→ Chassis ground - - -