Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgment Value
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| All transmission range switches OFF
NOTE:
"Transmission range switch OFF" is defined as transmission range switch input voltage ≥ 4.1 V.
|
True |
Time Needed for Diagnosis: 3 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.