  1. Measure the voltage between connector terminal and chassis ground.

    Preparation tool: 

    Circuit tester 

    Fig 1: Turn Signal Light & Hazard Light Module Connector Terminal Identification
    G10270697Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    4 (+) - Chassis ground (-) Always 10 - 14 V
    1 (+) - Chassis ground (-) IG OFF → ON Less than 1 V → 10 - 14 V

    Repair or replace the harness if the inspection result is not within the standard value.

  2. Measure the resistance between connector terminal and chassis ground.
    Terminal No. Inspection conditions Standard
    7 - Chassis ground Always Less than 1 Ω

    Repair or replace the harness if the inspection result is not within the standard value.

  3. Connect the connector.
  4. Measure the voltage between connector terminal and chassis ground.
Terminal No. Input/Output Inspection conditions Standard
6 (+) - Chassis ground (-) Input Turn signal switch (right) OFF → ON 9 V or more → less than 1 V
5 (+) - Chassis ground (-) Input Turn signal switch (left) OFF → ON 9 V or more → less than 1 V
8 (+) - Chassis ground (-) Input Hazard switch OFF → ON 9 V or more → less than 1 V
2 (+) - Chassis ground (-) Output Turn signal switch (right) OFF → ON Repeat less than 1 V → less than 1 V ←→ more than 9 V at 60 to 120 times per minute.
3 (+) - Chassis ground (-) Output Turn signal switch (left) OFF → ON Repeat less than 1 V → less than 1 V ←→ more than 9 V at 60 to 120 times per minute.
2 (+) - Chassis ground (-) Output Hazard switch OFF → ON Repeat less than 1 V → less than 1 V ←→ more than 9 V at 60 to 120 times per minute.
3 (+) - Chassis ground (-) Output Hazard switch OFF → ON Repeat less than 1 V → less than 1 V ←→ more than 9 V at 60 to 120 times per minute.

Replace the turn signal and hazard module if the inspection result is not within the standard value.