Check With SUBARU Select Monitor

CAUTION: Check whether the Rr Defogger op. mode setting is in initial setting or customize setting before performing inspection.
  1. Check the input signal when the rear window defogger switch is operated using Subaru Select Monitor.
    1. Prepare the Subaru Select Monitor. <Ref. to PREPARATION TOOL , General Description.>
    2. Turn the ignition to ON (engine OFF) and run the "PC application for Subaru Select Monitor".
    3. On «Main Menu» display, select «Each System Check».
    4. On «System Selection Menu» display, select «Integ. unit mode».
    5. On «Integ. unit mode failure diag.» display, select «Current Data Display & Save».
    6. Select «Auto A/C ECU Setting» from «Current Data Display & Save».
    7. Check the vehicle equipment and the settings of body integrated unit.
    8. Select the «Rr Defogger output» on «Current Data Display & Save».
    9. Check the displayed data (ON/OFF) by operating the rear window defogger switch.
  2. Check the operation with rear window defogger switch ON.
    • When customize setting is set as "Continuous", it is normal if the 15-minute operation and 2-minute stop repeats.
    • When customize setting is "Normal", it is normal if the operation lasts for 15 minutes and then turns OFF.
  3. When the operation in 2) above fails, replace the body integrated unit.