Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnosis 1 | |
| (Measured primary pulley shaft speed/Measured secondary pulley shaft speed) | < 0.36 or > 2.80 |
| Diagnosis 2 | |
| Measured primary pulley shaft speed | > 7140 rpm |
Time Needed for Diagnosis: 5 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- ENGINE TYPE EZ
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Engine speed - Measured primary pulley shaft speed | > Table 1 rpm |
ENGINE SPEED SPECIFICATION
| Measured primary pulley shaft speed (rpm) | 0 | 500 | 1000 | 1500 | 2000 | 2500 | 3000 | 3500 | 4000 | 4500 | 5000 | 5500 | 6000 | 6500 | 7000 |
| Engine speed - Measured primary pulley shaft speed (rpm) | 3700 | 3227 | 2755 | 2282 | 1856 | 1519 | 1213 | 956 | 786 | 713 | 651 | 601 | 569 | 544 | 520 |
Time Needed for Diagnosis: 10 seconds