Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Max. - min. values of fuel level output | < 2.6 l (0.69 US gal, 0.57 Imp gal) |
Time Needed for Diagnosis: Less than 1 second
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.