LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2015 >> Outback 2.5i >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Controls (Diagnostics) (H4DO) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P2195 O2 Sensor Signal Biased/Stuck Lean (Bank 1 Sensor 1) >> Wiring Diagram

DTC P2195 O2 Sensor Signal Biased/Stuck Lean (Bank 1 Sensor 1): Wiring Diagram

DIAGNOSTICS PROCEDURE

Step Check Yes No
1 CHECK FRONT OXYGEN (A/F) SENSOR CONNECTOR AND COUPLING CONNECTOR.  Has water entered the connector? Completely remove any water inside. Go to step .
2 CHECK HARNESS BETWEEN ECM AND FRONT OXYGEN (A/F) SENSOR CONNECTOR. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the connectors from ECM and front oxygen (A/F) sensor.
  3. Measure the resistance of harness between ECM connector and front oxygen (A/F) sensor connector.

    Connector & terminal 

    (E158) No. 46 - (E24) No. 3: 

    (E158) No. 33 - (E24) No. 4: 

Is the resistance less than 1 Ω? Go to step . Repair the open circuit of harness between ECM connector and front oxygen (A/F) sensor connector.
3 CHECK FOR POOR CONTACT. 
Check for poor contact of the front oxygen (A/F) sensor connector.
Is there poor contact of front oxygen (A/F) sensor connector? Repair the poor contact of front oxygen (A/F) sensor connector. Replace the front oxygen (A/F) sensor. <Ref. to FRONT OXYGEN (A/F) SENSOR .>