LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2015 >> Forester 2.0XT Premium >> Repair and Diagnosis >> Electrical >> Charging Systems >> Starting System / Charging System (H4DO) >> Battery Current Sensor & Battery Temperature Sensor >> Installation

Battery Current Sensor & Battery Temperature Sensor: Installation

Install in the reverse order of removal.

CAUTION:
  • Hold the terminal bracket with your hand when tightening the nut to avoid deforming the bracket.
  • Install the terminal bracket so that it is level to the battery.
  • While working, be sure to protect metal parts with cloth.

Tightening torque: 7.5 N.m (0.8 kgf-m, 5.5 ft-lb)