Current Data Display & Save/System Operation Check Mode
- Inspection with SSM3
- [Current Data Display & Save]
- Use the SSM3 and the [Current Data Display & Save] to determine functionality and narrow down the defective part.
Criteria
SSM3 screen: [Each System Check]→ [Integ. unit mode]→ [Current Data Display & Save]
CRITERIA SPECIFICATIONItem Name Description/display range Normal value Remarks [Trunk/BDoor Open SW] Trunk opening switch assembly status Display range: ON - OFF ON: the switch is pressed in
OFF: the switch is not pressed in-
- Use the SSM3 and the [Current Data Display & Save] to determine functionality and narrow down the defective part.
- System Operation Check Mode
- [Current Data Display & Save]