| Battery power supply |
B281 |
6 |
9 - 16 V |
| 7 |
| Ignition power supply |
B280 |
32 |
10 - 15 V when ignition switch is at ACC. |
| B281 |
3 |
10 - 15 V when ignition switch is at ON or START. |
| TCM ("P" range) |
B281 |
20 |
Can not be measured because of digital communication |
| 28 |
| Stop light and brake switch |
B280 |
10 |
9 - 16 V when the stop light & brake switch is ON. 0 V when the stop light & brake switch is OFF. |
| "P" range switch |
B281 |
18 |
0 V when select lever is in "P" range. 9 - 16 V when select lever is in other positions than "P" range. |
| Shift lock solenoid signal |
B281 |
5 |
8.5 - 16 V when shift lock is released. 0 V when shift lock is operating. |
| Key warning switch signal |
B280 |
4 |
9 - 16 V when key is inserted. 0 V when key is removed. |
| Key lock solenoid signal |
B281 |
4 |
7.5 - 16 V when the key is inserted with the select lever shifted in positions other than "P" range. 0 V at other conditions than above. |
| Ground |
B280 |
1 |
- |
| B281 |
31 |
| i84 |
1 |
| i171 |
29 |
| Delivery (test) mode signal |
i84 |
27 |
Can not be measured because of digital communication |
| 35 |