Enable Condition
ENABLE CONDITION
| Secondary Parameters | Enable Conditions |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Elapsed time after starting the engine | > 1 s |
| Engine speed | > 500 rpm |
| Injection time | ≥ 1000 μs |
| and | |
| < 120000000/engine speed - 1000 μs | |
| Injection status | Not during fuel cut |
| and | |
| Not during asynchronous injection controlled by crankshaft position sensor |