LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Tribeca >> Repair and Diagnosis >> Electrical >> Charging Systems >> Starting System & Charging System >> Starter >> Inspection >> Switch Assembly Operation

Switch Assembly Operation

NOTE: Perform each test in a short period of time (3 - 5 sec).
  1. Suction test

    Check that the pinion gear comes flying out when the harness is disconnected from terminal M and connected as shown in the figure.

    Fig 1: Performing Suction Test
    G08544559Courtesy of SUBARU OF AMERICA, INC.
  2. Holding test

    Check that the pinion gear remains flying out after the cable is disconnected from terminal M.

    Fig 2: Performing Holding Test
    G08544560Courtesy of SUBARU OF AMERICA, INC.
  3. Returning test

    With terminal S connected to the positive terminal, and terminal M and starter body connected to the battery ground terminal to suction the main contact point, check that the pinion gear returns to its original position when terminal S is disconnected.

    Fig 3: Performing Returning Test
    G08544561Courtesy of SUBARU OF AMERICA, INC.