Check Hazard Light Operation
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK HAZARD LIGHT OPERATION. Make sure the hazard light blinks when hazard switch is turned to ON. |
Does the hazard light blink? | Go to step 2 . | Check the hazard light circuit. |
2 CHECK OUTPUT TO HAZARD LIGHT.
|
Is output signal present when operating the transmitter LOCK/UNLOCK button? | Go to step 4 . | Go to step 3 . |
| 3 CHECK KEYLESS ENTRY OPERATION. Press the LOCK/UNLOCK button of the keyless transmitter. |
Does it operate properly? | Replace the body integrated unit. Refer to BODY INTEGRATED UNIT . | Check keyless entry system. Refer to SYMPTOM CHART . |
4 CHECK HARNESS BETWEEN HAZARD LIGHT AND BODY INTEGRATED UNIT.
|
Is the resistance less than 10 Ω? | Check body integrated unit. Refer to BASIC DIAGNOSTIC PROCEDURE . | Repair or replace the harness. |