  1. Cooling fan relay check
    1. Check the resistance between connector terminals.
      STANDARD VALUE RESISTANCE SPECIFICATION

      Inspection terminals Inspection conditions Standard value
      3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
      3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
      G12587152Courtesy of SUBARU OF AMERICA, INC.
  2. Cooling fan relay NO. 2 check
    1. Check the resistance between connector terminals.
      STANDARD VALUE RESISTANCE SPECIFICATION

      Inspection terminals Inspection conditions Standard value
      3 - 4 When the battery voltage is not applied to the terminal 1 and terminal 2: Less than 1 Ω
      3 - 4 When the battery voltage is applied to the terminal 1 and terminal 2: 10 k Ωor more
      3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
      3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
      G12587153Courtesy of SUBARU OF AMERICA, INC.
  3. Cooling fan relay NO. 3 check
    1. Check the resistance between connector terminals.
      STANDARD VALUE RESISTANCE SPECIFICATION

      Inspection terminals Inspection conditions Standard value
      3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
      3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
      G12587154Courtesy of SUBARU OF AMERICA, INC.