LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> BRZ Limited, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 41 (Lighting System (Exterior)) >> Auto Leveling System >> Headlight Leveling Motor Circuit >> Inspection steps

Inspection steps

WARNING: This page is about a different car, the 2018 Subaru BRZ. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: After replacing the headlight leveling computer ASSY, initialization is required. (Refer to AUTO LEVELING SYSTEM )
  1. Inspection of the wiring harnesses and connectors (headlight leveling computer ASSY - headlight ASSY)
    1. Disconnect the connector A16 of the headlight leveling computer ASSY.
    2. Disconnect the connector A62 of the headlight ASSY LH, or connector A40 of the headlight ASSY RH.
    3. Measure the resistance according to the following chart. Resistance (open circuit check)
      STANDARD VALUE SPECIFICATION - LH SIDE

      Inspection terminals (Terminal symbol) Inspection conditions Standard value
      A16-11 (LH1) - A62-3 (LHB1) Always Less than 1 Ω
      A16-18 (LH2) - A62-2 (LHM+) Always Less than 1 Ω
      A16-24 (LH3) - A62-1 (LHE) Always Less than 1 Ω
      STANDARD VALUE SPECIFICATION - RH SIDE

      Inspection terminals (Terminal symbol) Inspection conditions Standard value
      A16-10 (RH1) - A40-3 (RHB1) Always Less than 1 Ω
      A16-17 (RH2) - A40-2 (RHM+) Always Less than 1 Ω
      A16-23 (RH3) - A40-1 (RHE) Always Less than 1 Ω

      Resistance (short circuit check)

      STANDARD VALUE SPECIFICATION - LH SIDE

      Inspection terminals (Terminal symbol) Inspection conditions Standard value
      A16-11 (LH1) - Chassis ground Always 10 kΩ or more
      A16-18 (LH2) - Chassis ground Always 10 kΩ or more
      A16-24 (LH3) - Chassis ground Always 10 kΩ or more
      STANDARD VALUE SPECIFICATION - RH SIDE

      Inspection terminals (Terminal symbol) Inspection conditions Standard value
      A16-10 (RH1) - Chassis ground Always 10 kΩ or more
      A16-17 (RH2) - Chassis ground Always 10 kΩ or more
      A16-23 (RH3) - Chassis ground Always 10 kΩ or more

      OK: Go to next step

      NG: Repair or replacement of wiring harness or connector

  2. Replacement of the headlight leveling computer ASSY
    1. Replace with a new or normal headlight leveling computer ASSY. (Refer to HEADLIGHT LEVELING COMPUTER )
  3. Operation inspection
    1. Inspect the operation of the headlight leveling motors. (Refer to LIGHTING SYSTEM ) Criteria: The headlight leveling motors operate normally.
      RESULT DESCRIPTION

      Item Go to
      Both headlight leveling motors operate. A
      The right headlight leveling motor does not operate. B
      The left headlight leveling motor does not operate. C
      1. Go to next step
      2. Replacement of the headlight ASSY RH (Refer to HEADLIGHTS )
      3. Replacement of the headlight ASSY LH (Refer to HEADLIGHTS )

      Complete (Faulty headlight leveling computer ASSY)