Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE CHART
| Malfunction criteria | Threshold value |
|---|---|
| Throttle sensor opening angle at full close point learning | < 9.884 ° or > 20.116 ° |
| or | |
| Throttle opening angle when the ignition switch is ON - Throttle minimum stop position | < 0.887 ° |
Time Needed for Diagnosis: 8 ms - 80 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE CHART
| Malfunction criteria | Threshold value |
|---|---|
| Throttle sensor opening angle at full close point learning | ≥ 9.884 ° and ≤ 20.116 ° |
| Throttle opening angle when the ignition switch is ON - Throttle minimum stop position | ≥ 0.887 ° |
Time Needed for Diagnosis: 8 ms