Trunk Opener Cancel Button
- Disconnect the trunk opener cancel button connector.
- Measure the resistance between trunk opener cancel button terminals.
Preparation tool: Circuit tester
Terminal No. Inspection conditions Specification 1 - 2 Switch ON Less than 1 Ω Switch OFF 1 MΩ or more - Replace the trunk opener button if the inspection result is not within the standard value.