Enable Conditions
ENABLE CONDITION REFERENCE CHART
| Secondary Parameters | Enable Conditions |
| Battery voltage Elapsed time after starting the engine Engine speed Injection time Injection status |
≥ 10.9 V > 1 s > 500 rpm ≥ 1000 μ and < 120000000/engine speed - 1000 μ Not during fuel cut and Not during asynchronous injection controlled by crankshaft position sensor |