Diagnostic Method
- Abnormality Judgment
Judge as NG when the status where the number of camshaft position sensor signal in two engine revolutions is less than 3 time(s).
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Amount of camshaft sensor signal during 2 revs. | < 3 time(s) |
Time Needed for Diagnosis: 2 engine revs. x 50
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG when the malfunction criteria below are met.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Camshaft position sensor signal | ≥ 3 time(s) |
Time Needed for Diagnosis: Two engine revolutions