Enable Conditions
ENABLE CONDITIONS
| Secondary Parameters | Enable Conditions |
|---|---|
| Time of establishing all secondary parameter conditions | ≥ 2000 ms |
| Battery voltage | ≥ 10.9 V |
| Engine speed | ≥ 1500 RPM |
| Engine coolant temperature | ≥ 50°C(122°F) |
| Exhaust AVCS control | Operation |
| Target timing advance change amount (per 64 ms) | <1.07°CA |