Diagnostic Method
When a misfire occurs, the engine speed will decreased and the crankshaft position speed will change. Calculate the interval difference value (diagnostic value) from crankshaft position speed by the following formula, and judge whether a misfire is occurring or not comparing the calculated result with judgement value. Counting the number of misfires. If the misfire ratio is higher during 1000 revs, or 200 revs. Judge corresponding cylinders as NG.
| Diagnostic value calculation (Calculate from angle speed) → | Misfire detection every single ignition (Compare diagnostic value with judgement value) → | NG judgement (Misfire occurrence judgement required by the law) (Compare number of misfire with judgement) |
|
|
As shown in the following figure, pick a cylinder as the standard and name it omg 0. And the former crankshaft position speed is named omg 1, the second former crankshaft position speed is named omg 2, the third is named omg 3, etc.
120° Interval Difference Method
| Diagnostic value | domg 120 = (omg 1 - omg 0)-(omg 7 - omg 1)/6 |
Judge as a misfire in the following cases.
(Judgement value before 120° CA) |
|
360° Interval Difference Method
| Diagnostic value | domg 360 = (omg 1 - omg 0)-(omg 4 - omg 3) |
| Misfire judgement | domg 360 > Judgement value → Judge as misfire |
720° Interval Difference Method
| Diagnostic value | domg 720 = (omg 1 - omg 0)-(omg 7 - omg 6) |
| Misfire judgement | domg 720 > Judgement value → Judge as misfire |
- FTP 1.5 times misfire (Misfire occurrence level which influences exhaust gas)
- Abnormality Judgement
Judgement Value (Judge that malfunction occurs when the misfire ratio is high in 1000 engine revs.)
| Malfunction Criteria | Threshold Value |
|---|---|
| FTP emission judgement value | ≥ 50 x 100/3000% in 1000 revs. |
Time Needed for Diagnosis: 1000 engine revs.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgement
Judgement Value
| Malfunction Criteria | Threshold Value |
|---|---|
| FTP emission judgement value | < 50 x 100/3000% in 1000 revs. |
Time Needed for Diagnosis: 1000 engine revs.
- Catalyst damage misfire (Misfire occurrence level damaging catalyst)
- Abnormality Judgement
Judgement Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Catalyst damage misfire judgement value | ≥ Value of Map 3 |
Map 3
| Intake air (g(oz)/rev) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2 (0.01) | 0.4 (0.01) | 0.6 (0.02) | 0.8 (0.03) | 1 (0.04) | 1.2 (0.04) | 1.4 (0.05) | 1.6 (0.06) | 1.8 (0.06) | 2 (0.07) | ||
| Engine speed (RPM) | 700 | 90 | 90 | 88 | 76 | 68 | 68 | 68 | 68 | 68 | 68 |
| 1000 | 90 | 90 | 88 | 76 | 68 | 68 | 68 | 68 | 68 | 68 | |
| 1500 | 89 | 88 | 80 | 64 | 56 | 56 | 56 | 56 | 56 | 56 | |
| 2000 | 88 | 84 | 64 | 40 | 36 | 35 | 35 | 35 | 35 | 35 | |
| 2500 | 88 | 80 | 56 | 36 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 3000 | 64 | 56 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 3500 | 50 | 40 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 4000 | 40 | 38 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 4500 | 50 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 5000 | 40 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 5500 | 40 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 6000 | 36 | 36 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 6500 | 32 | 32 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| 7000 | 32 | 32 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
Time Needed for Diagnosis: 200 engine revs.
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgement
Judgement Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Catalyst damage misfire judgement value | < Value of Map 2 |
Time Needed for Diagnosis: 200 engine revs.