Enable Condition
ENABLE CONDITION REFERENCE
| Secondary Parameters | Enable Conditions |
|---|---|
| Time of establishing all secondary parameter conditions | ≥ 5000 ms |
| Battery voltage | ≥ 10.9 V |
| Engine speed | ≥ 1500 RPM |
| Engine coolant temperature | ≥ 50 °C (122 °F) |
| Exhaust AVCS control | Operation |
| Target timing advance change amount (per 64 ms) | < 1.07 °CA |