Check Power Supply And Ground Circuit
DIAGNOSIS PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK POWER SUPPLY OF BODY INTEGRATED UNIT.
|
Is the data display 10 V or more (BATT voltage (Control), BATT voltage (BACKUP))? | Body integrated unit is normal. | Go to step 2. |
2 CHECK POWER SUPPLY.
|
Is the voltage 10 V or more? | Go to step 3. | Check the harness for open or short circuit between body integrated unit and fuse. |
| 3 CHECK GROUND CIRCUIT. Measure the resistance between harness connector terminal and chassis ground. Connector & terminal (i84) No. 21 - Chassis ground: (B280) No. 22 - Chassis ground: (B281) No. 8 - Chassis ground: (B281) No. 9 - Chassis ground: |
Is the resistance less than 10 Ω? | Replace the body integrated unit. Ref. to BODY INTEGRATED UNIT . | Repair or replace the harness. |