Check Ignition Switch Illumination
DIAGNOSIS PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK FUSE. Remove and visually check the fuse No. 14 (in the main fuse box). |
Is the fuse blown out? | Replace the fuse with a new part. | Go to step 2. |
2 CHECK POWER SUPPLY.
|
Is the voltage 10 V or more? | Go to step 3. | Check the harness for open circuits and shorts between the ignition switch illumination and fuse. |
3 CHECK IGNITION SWITCH ILLUMINATION CIRCUIT.
|
Is the resistance less than 10 Ω? | Go to step 4. | Check the harness for open circuits and shorts between the body integrated unit and ignition switch illumination. |
4 CHECK IGNITION SWITCH ILLUMINATION BULB.
|
Does the bulb illuminate? | Replace the body integrated unit. Ref. to BODY INTEGRATED UNIT . | Replace the ignition switch illumination bulb with a new part. |