Impact Sensor Setting Using SUBARU Select Monitor
- Prepare the Subaru Select Monitor kit. Ref. to SPECIAL TOOL , PREPARATION TOOL, General Description.
- Prepare PC with Subaru Select Monitor installed.
- Connect the USB cable between SDI (Subaru Diagnosis Interface) and USB port on the personal computer (dedicated port for the Subaru Select Monitor).NOTE: The dedicated port for the Subaru Select Monitor means the USB port which was used to install the Subaru Select Monitor.
- Connect the diagnosis cable to SDI.
- Connect SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).CAUTION: Do not connect scan tools other than the Subaru Select Monitor.
- Start the PC.
- Turn the ignition switch to ON (engine OFF) and run the "PC application for Subaru Select Monitor".
- On the «System Selection Menu» display, select the {Integ. unit mode}.
- Select {ECM customizing}.
- Make a impact monitor setting.
- When installing: ON
- When removing: OFF
- Make a impact monitor ON/OFF setting.
- When installing: ON
- When removing: OFF
- Turn the ignition switch to OFF, and then remove the Subaru Select Monitor.