LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2009 >> Impreza WRX STi >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Engine (Diagnostics) (STI) >> System Operation Check Mode >> Operation >> Idling Ignition Timing Fixed

Idling Ignition Timing Fixed

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Refer to OPERATION , Clear Memory Mode.
  1. On «System Operation Check Mode» display, select {Fixed Idle Ignition Timing}.
  2. On «Start the Engine» display, start the engine and click the [OK] button.
  3. On «Fixed Idle Ignition Timing» display, click the [Execution] button and execute the idling ignition timing fixed.
  4. Click the [Cancel] button to stop the idling ignition timing fixed.
  5. Click the [[F12] Exit] button to end the idling ignition timing fixed. The screen will return to the «System Operation Check Mode» screen.
    NOTE: For detailed operation procedures, refer to "Subaru Select Monitor ".