LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2009 >> Forester XT >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Engine Cooling System - Cooling (H4SO)) >> General Description >> Specification

Section 5 (Engine Cooling System - Cooling (H4SO)): General Description: Specification

WARNING: This page is about a different variant/trim than selected.
ENGINE COOLANT CAPACITY SPECIFICATION

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity (US qt, Imp qt) Non-turbo model MT: approx. 6.8 (7.2, 6.0)
AT: approx. 6.7 (7.1,5.9)
Turbo model Approx. 7.5 (7.9, 6.6)
Water pump Type Centrifugal impeller type
Discharge performance I Discharge rate (US gal, Imp gal) /min 20 (5.3, 4.4)
Pump speed - Discharge pressure 760 rpm - 2.9 kPa (0.3 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance II Discharge rate (US gal, Imp gal) /min 100 (26.4, 22.0)
Pump speed - Discharge pressure 3,000 rpm - 49 kPa (5.0 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance III Discharge rate (US gal, Imp gal) /min 200 (52.8, 44.0)
Pump speed - Discharge pressure 6,000 rpm - 225.4 kPa (23 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 76 (2.99)
Number of impeller vanes 8
Pump pulley diameter mm (in) 60 (2.36)
Clearance between impeller and case Standard mm (in) 0.5-1.5 (0.020 - 0.060)
Thermostat Type Wax pellet type
Starting temperature to open 80-84°C (176-183°F)
Fully opens 95°C (203°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35 (1.38)
Radiator fan Motor input Main fan 90 W
Sub fan 90 W
Fan diameter/Blade Main fan 300 mm (11.81 in)/4
Sub fan 300 mm (11.81 in)/5
Radiator Type Down flow, pressure type
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 16 (27.06 x 13.39 x 0.63)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Above: 108±15 or more
(1.1±0.15, 16±2)
Below: -1.0 to -4.9 or less
(-0.01- -0.05, -0.1- -0.7)
Fins Corrugated fin type
Reservoir tank Capacity (US qt, Imp qt) 0.45 (0.48, 0.40)
RECOMMENDED MATERIALS SPECIFICATION

  Recommended materials Item number Alternative
Coolant SUBARU SUPER COOLANT (concentrated type) - -
SUBARU SUPER COOLANT (dilution type) K0670Y0000
Water for dilution Distilled water - Soft water or tap water
Cooling system protective agent Cooling system conditioner SOA345001 -