Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCEMalfunction criteria Threshold value Sub feedback learning value ≥ 0.031 Time Needed for Diagnosis: 5 s x 1 time
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCEMalfunction criteria Threshold value Sub feedback learning value < 0.031 +0 Time Needed for Diagnosis: 5 s