Diagnostic Method
After establishing the execution conditions, calculate the front oxygen (A/F) sensor lambda deviation cumulative value (Σ |(sglmdn - sglmdnn-1 )|) and rear oxygen sensor output voltage deviation cumulative value (Σ |(ro2sadn - ro2sadn-1 )|) per 32 milliseconds x 4, and when the front oxygen (A/F) sensor lambda deviation cumulative value (Σ |(sglmdn - sglmdn-1 )|) becomes the predetermined value or more, calculate the diagnostic value.
- Abnormality Judgment
If the duration of time while the following conditions are met is within the time indicated, judge as NG.
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCEMalfunction criteria Threshold value Σ |(ro2sadn - ro2sadn-1 )| / Σ |(sglmdn - sglmdnn-1 )| > 25 Time Needed for Diagnosis: 30 - 55 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is within the predetermined time.
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCEMalfunction criteria Threshold value Σ |(ro2sadn - ro2sadn-1 )| / Σ |(sglmdn - sglmdn-1 )| < 25 Time Needed for Diagnosis: 30 - 55 seconds