Diagnostic Method
- Abnormality Judgment
Judge as NG when the following conditions are established.
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCEMalfunction Criteria Threshold Value Output voltage difference between Max. and Min. < 0.02 V (Equivalent to approximately 0.5°C (0.9°F) near 25°C) Time Needed for Diagnosis: Less than 1 second
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCEMalfunction Criteria Threshold Value Output voltage difference between Max. and Min. ≥ 0.02 V Time Needed for Diagnosis: Less than 1 second