LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2008 >> Outback Base, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 35 (Cooling System (H4DOTC)) >> General Description >> Specification

Section 35 (Cooling System (H4DOTC)): General Description: Specification

WARNING: This page is about a different car, the 2006 Subaru Outback and 2006 Subaru Legacy. However, it is still accessible from the selected car via links, so may be relevant.
GENERAL SPECIFICATIONS

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity l  (US qt, Imp qt) MT: Approx. 7.3 (7.7, 6.4)
AT: Approx. 7.2 (7.6, 6.3)
Water pump Type Centrifugal impeller type
Discharge performance I Discharge rate l  (US gal, Imp gal) /min 20 (5.3, 4.4)
Pump speed - Discharge pressure 760 rpm - 2.9 kPa (0.3 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance II Discharge rate l  (US gal, Imp gal) /min 100 (26.4, 22.0)
Pump speed - Discharge pressure 3,000 rpm - 49.0 kPa (5.0 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance III Discharge rate l  (US gal, Imp gal) /min 200 (52.8, 44.0)
Pump speed - Discharge pressure 6,000 rpm - 225.4 kPa (23.0 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 76 (2.99)
Number of impeller vanes 8
Pump pulley diameter mm (in) 60 (2.36)
Clearance between impeller and case Standard mm (in) 0.5 - 1.5 (0.020 - 0.059)
Thermostat Type Wax pellet type
Starting temperature to open 76 - 80°C (169 - 176°F)
Fully opens 91°C (196°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35 (1.38)
Radiator fan Motor input Main fan W 120
Sub fan W 120
Fan diameter / Blade Main fan 320 mm (12.6 in)/5
Sub fan 320 mm (12.6 in)/7
Radiator Type Down flow
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 16 (27.06 x 13.39 x 0.63)
Pressure range in which cap valve is open Coolant filler tank side kPa (kg/cm2 , psi) Above: 108±15 (1.1±0.15, 16±2)
Below:-1.0 - -4.9 (-0.01 - -0.05, -0.1 - -0.7)
Radiator side kPa (kg/cm2 , psi) Above only: 137±14.7 (1.40±0.15, 20±2.1)
Fins Corrugated fin type
Reservoir tank Capacity l  (US qt, Imp qt) 0.45 (0.48, 0.40)
GENERAL SPECIFICATIONS

Vehicle speed A/C compressor load Engine coolant temperature
Increase: 94°C (201°F) or less
Decrease: 91 °C (196°F) or less
Increase: 95 - 96°C (203 - 205°F)
Decrease: 92 - 94°C (198 - 201°F)
Increase: 97°C (207°F) or more
Decrease: 95°C (203°F) or more
Radiator fan operation Radiator fan operation Radiator fan operation
During acceleration: 19 km/h (12 MPH) or less
During deceleration: 10 km/h (6 MPH) or less
OFF OFF Low-Speed High-Speed
Low Low-Speed Low-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 20 - 69 km/h (12 - 43 MPH)
During deceleration: 11 - 64 km/h (7 - 40 MPH)
OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 70 - 105 km/h (43 - 65 MPH)
During deceleration: 65 - 100 km/h (40 - 62 MPH)
OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 106 km/h (66 MPH) or more
During deceleration: 101 km/h (63 MPH) or more
OFF OFF High-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed