LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2008 >> Outback Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 182 (LAN Communication System - LAN System (Diagnostics)) >> Subaru Select Monitor >> Operation >> Function Setting (ECM Customizing)

Function Setting (ECM Customizing)

WARNING: This page is about a different car, the 2008 Subaru Impreza. However, it is still accessible from the selected car via links, so may be relevant.
  1. On the «Main Menu» display screen, select the {Each System Check}.
  2. On the «System Selection Menu» display screen, select the {Integ. Unit mode}.
  3. On the «Integ. unit mode failure diag» display screen, select the {Unit customization}.
  4. Change the setting with UP/DOWN key and set with the [OK] key.
    • List of function setting item (ECM customizing)
    DATA INITIAL SETTING VALUE

    Data Initial setting value Customize setting Remarks
    Off delay time Normal   Delay time below can be selected by setting.
    After door closed After keyless unlock
    OFF 0 seconds 0 seconds
    Short 3 seconds 10 seconds
    Normal 5 seconds 20 seconds
    Long 8 seconds 30 seconds
    Auto lock time 30 sec. 0 - 60 sec. Workable when Auto locking is set to "ON" and Automatic locking setup is "ON". Time can be changed by 10 seconds: 0 (OFF) - 60 (maximum).
    Rr defogger op. mode 15 min. 15 min. Wiper deicer stops in 15 minutes automatically after switch is turned to ON.
    Continuous The wiper deicer activates for 15 minutes and turns inactive for 2 minutes repeatedly until the switch is turned OFF.
    Wiper deicer op. mode 15 min. 15 min. Wiper deicer stops in 15 minutes automatically after switch is turned to ON.
    Continuous The wiper deicer activates for 15 minutes and turns inactive for 2 minutes repeatedly until the switch is turned OFF.
    Security Alarm Setup OFF ON Security alarm (hazard, horn or siren) in active condition
    OFF Security alarm in inactive condition
    Impact Sensor Setup OFF ON Workable when Impact Sensor Setup is set to "ON". Impact sensor function becomes activated.
    OFF Impact sensor in inactive condition (Set to "OFF" in models without sensors.)
    Alarm monitor delay setting ON   After the keyless lock operation, the alarm monitor starts after the following delay time has passed.
    ON Delay time is 30 seconds.
    OFF Delay time is 0 seconds.
    Lockout prevention ON ON Lockout prevention in inactive condition (The function does not operate if safety knob is locked by hand.)
    OFF Lockout prevention in inactive condition
    Impact Sensor (optional) OFF ON Vehicle is controlled in impact sensor equipped mode. (Make sure to set to OFF for models without the impact sensor. When set to ON, hazard, the horn or siren will operate after doors are locked by the keyless entry system operation (Alarm monitor start).)
    OFF Vehicle is controlled in no impact sensor mode.
    Siren setting (optional) OFF ON Make sure to set to OFF for models without the siren.
    OFF
    Answer-back buzzer setup ON ON Workable when answer-back buzzer setup is set to "ON". When lock/unlock is selected by keyless entry system operated, hazard answer-back buzzer operates.
    OFF When lock/unlock is selected by keyless entry system operated, answer-back buzzer does not sound.
    Hazard answer-back setup ON ON Workable when hazard answer-back setup is set to "ON" When lock/unlock is selected by keyless entry system operated, hazard answer-back buzzer operates.
    OFF When lock/unlock is selected by keyless entry system operated, hazard answer-back does not operate.
    Automatic locking setup ON ON Not supported
    OFF
    Ans.-back Buzzer ON ON Vehicle is controlled in answer-back buzzer equipped mode.
    OFF Vehicle is controlled in answer-back buzzer non-equipped mode. (Make sure to set to "OFF" in models without answer back buzzers.)
    Auto locking ON ON Not supported
    OFF
    Initial Keyless Setting - - -
    Execution Settings of keyless entry system are initialized. (No. 2: 30 sec, No. 11: ON, No. 12: ON, No. 13: ON, No. 14: ON)
    Initial button setting - - -
    Execution Settings of each function are initialized. (No. 1: Normal, No. 3: 15 min., No. 4:15 min., No. 8: ON)
    Initial Security setting - - Not supported
    Execution
    Passive arming OFF ON Setting only for North American models
    OFF
    Door open warning (prevention of battery run-out) OFF ON If detecting door open for 30 minutes, room light, key ring illumination are turned OFF to prevent battery run-out.
    OFF Room light, key illumination and door warning light is not turned OFF.
    (Particular) Security setting OFF ON Setting only for UK models (if selected, display returns to «System Selection Menu» screen.)
    Outside Temp Offset 0 + 2.0°C - 2.0° (0.5°C increments) For adjustment of outside temperature
    Belt warning Switch ON ON When using normally
    OFF Stop the belt warning buzzer beep and warning light illumination.
  5. After setting, make sure that vehicle equipment is same as the setting changed in the {Current Data Display & Save}.
CAUTION:
  • The above settings must match the actual vehicle equipment.
  • Do not change settings other than the above while setting the functions.
  • Be sure not to change Factory initial setting except installation of new body integrated unit.
NOTE: For details concerning the operation procedure, refer to the help file on PC application for Subaru Select Monitor.