GENERAL SPECIFICATION

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity (US qt, lmp qt) MT: approx. 6.8 (7.2, 6.0)
AT: approx. 6.7 (7.1, 5.9)
Water pump Type Centrifugal impeller type
Discharge performance I Discharge rate (US gal, lmp gal) /min 20 (5.3, 4.4)
Pump speed - Discharge pressure 760 rpm - 2.9 kPa (0.3 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance II Discharge rate (US gal, lmp gal) /min 100 (26.4, 22.0)
Pump speed - Discharge pressure 3,000 rpm - 49 kPa (5.0 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance III Discharge rate (US gal, lmp gal) /min 200 (52.8, 44.0)
Pump speed - Discharge pressure 6,000 rpm - 225.4 kPa (23 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 76 (2.99)
Number of impeller vanes 8
Pump pulley diameter mm (in) 60 (2.36)
Clearance between impeller and case Standard mm (in) 0.5 - 1.5 (0.020 - 0.060)
Thermostat Type Wax pellet type
Starting temperature to open 80 - 84°C (176 - 183°F)
Fully opens 95°C (203°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35 (1.38)
Radiator fan Motor input Main fan 90 W
Sub fan 90 W
Fan diameter / Blade Main fan 300 mm (11.81 in)/4
Sub fan 300 mm (11.81 in)/5
Radiator Type Down flow, pressure type
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 16 (27.06 x 13.39 x 0.63)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Above: 108 ± 15 or more (1.1 ± 0.15, 16 ± 2) Below: -1.0 to -4.9 or less (-0.01- -0.05,-0.1- -0.7)
Fins Corrugated fin type
Reservoir tank Capacity (US qt, lmp qt) 0.45 (0.48, 0.40)
GENERAL SPECIFICATION

Coolant Recommended materials Item number Alternative
Coolant SUBARU coolant 000016218 Phosphoric acid (non-amine) type
Water for dilution Distilled water - Soft water or tap water
Cooling system protective agent Cooling system conditioner SOA345001 None
GENERAL SPECIFICATION

Vehicle speed A/C compressor load Engine coolant temperature
Increase: 95°C (203°F) or less Decrease: 92°C (198°F) or less Increase: 96 - 99°C (205 - 210°F) Decrease: 93 - 94°C (199 - 201°F) Increase: 100°C (212°F) or more Decrease: 95°C (203°F) or more
Radiator fan operation Radiator fan operation Radiator fan operation
During acceleration: 19 km/h (12 MPH) or less During deceleration: 10 km/h (6 MPH) or less OFF OFF Low-Speed High-Speed
Low Low-Speed Low-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 20 - 69 km/h (12 - 43 MPH) During deceleration: 11 - 64 km/h (7 - 40 MPH) OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 70 - 134 km/h (43 - 83 MPH) During deceleration: 65 - 129 km/h (40 - 80 MPH) OFF OFF Low-Speed High-Speed
Low OFF Low-Speed High-Speed
High Low-Speed High-Speed High-Speed
During acceleration: 135 km/h (84 MPH) or more During deceleration: 130 km/h (81 MPH) or more OFF OFF OFF High-Speed
Low OFF Low-Speed High-Speed
High OFF Low-Speed High-Speed