Check Output Signal To Body Integrated Unit
CHECK STEP FOR OUTPUT SIGNAL TO BODY INTEGRATED UNIT
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK OUTPUT SIGNAL. Measure the voltage between the keyless entry control module harness connector terminal and the chassis ground when the UNLOCK/DIS-ARM button of the transmitter is pressed. Connector & terminal (B176) No. 18 (+) - Chassis ground (-): |
Is the voltage 10 V or more? | Go to step 2. | Replace the keyless entry control module. |
| 2 CHECK OUTPUT SIGNAL. Measure the voltage between the keyless entry control module harness connector terminal and the chassis ground when the LOCK/ARM button of the transmitter is pressed. Connector & terminal (B176) No. 19 (+) - Chassis ground (-): |
Is the voltage 10 V or more? | Go to step 3. | Replace the keyless entry control module. |
3 CHECK HARNESS BETWEEN KEYLESS ENTRY CONTROL MODULE AND BODY INTEGRATED UNIT.
|
Is the resistance less than 10 Ω? | Replace the body integrated unit. | Check the harness for open or short circuits between the keyless entry control module and body integrated unit. |