Check Keyless Buzzer
DIAGNOSTIC PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK FUSE. Remove and check the fuse No. 2 (in the main fuse box). |
Is the fuse blown out? | Replace the fuse with a new one. | Go to step 2. |
2 CHECK FOR POWER SUPPLY OF KEYLESS BUZZER.
|
Is the voltage more than 10 V? | Go to step 3. | Check for open or short circuit in the harness between fuse and keyless buzzer. |
3 CHECK THE HARNESS BETWEEN KEYLESS BUZZER AND KEYLESS ENTRY CONTROL MODULE.
|
Is the resistance more than 10 Ω? | Go to step 4. | Repair the harness between keyless buzzer and keyless entry control module. |
| 4 CHECK KEYLESS BUZZER. Connect the positive terminal (+) of the battery to No. 2 terminal of the keyless buzzer connector, and the negative (-) terminal to No. 1 terminal. Check the buzzer sounds. |
Does the buzzer ring? | Replace the keyless entry control module. | Replace the keyless buzzer. |