Service Limit
Make a measurements as follows. If it exceeds the service limit, replace with a new one.
CAUTION:
- When securing the oil pump on a vise, hold the oil pump with the least possible force between two pieces of wood.
- Do not set the outside of flow control valve or pulley on a vise; otherwise outside or pulley might be deformed. Select properly sized wood pieces.
- Play of the pulley shaft
Condition:
P: When applying the force of 9.8 N (1.0 kgf, 2.2 lb)
Service limit:
Play in the radial direction
Less than 0.2 mm (0.008 in)
Axial play
Less than 0.6 mm (0.024 in)
- Deflection of the pulley groove
Service limit:
Less than 1.0 mm (0.039 in)
NOTE: Read the value for one surface of V ditch, and then the value for another off the dial. - Rotating resistance of pulley
Service limit:
Maximum load: 9.22 N (0.94 kgf, 2.07 lb) or less
NOTE:- A rather higher value may be indicated when pulley starts turning.
- Measure the load during rotation to make a judgment.