LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2006 >> Outback R >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Cooling System (H4DOTC)) >> General Description >> Specification

Section 18 (Cooling System (H4DOTC)): General Description: Specification

WARNING: This page is about a different variant/trim than selected.
GENERAL SPECIFICATIONS

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity (US qt, Imp qt) MT: Approx. 7.3 (7.7, 6.4)
AT: Approx. 7.2 (7.6, 6.3)
Water pump Type Centrifugal impeller type
Discharge performance I Discharge rate (US gal, Imp gal) /min 20 (5.3, 4.4)
Pump speed - Discharge pressure 760 rpm - 2.9 kPa (0.3 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance II Discharge rate (US gal, Imp gal) /min 100 (26.4, 22.0)
Pump speed - Discharge pressure 3,000 rpm - 49.0 kPa (5.0 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance III Discharge rate (US gal, Imp gal) /min 200 (52.8, 44.0)
Pump speed - Discharge pressure 6,000 rpm - 225.4 kPa (23.0 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 76 (2.99)
Number of impeller vanes 8
Pump pulley diameter mm (in) 60 (2.36)
Clearance between impeller and case Standard mm (in) 0.5 - 1.5 (0.020 - 0.059)
Thermostat Type Wax pellet type
Starting temperature to open 76 - 80°C (169 - 176°F)
Fully opens 91°C (196°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35 (1.38)
Radiator fan Motor input Main fan W 120
Sub fan W 120
Fan diameter / Blade Main fan 320 mm (12.6 in)/5
Sub fan 320 mm (12.6 in)/7
Radiator Type Down flow
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 16 (27.06 x 13.39 x 0.63)
Pressure range in which cap valve is open Coolant filler tank side kPa (kg/cm2 , psi) Above: 108±15 (1.1±0.15, 16±2)
Below:-1.0 - -4.9 (-0.01 - -0.05, -0.1 - -0.7)
Radiator side kPa (kg/cm2 , psi) Above only: 137±14.7 (1.40±0.15, 20±2.1)
Fins Corrugated fin type
Reservoir tank Capacity (US qt, Imp qt) 0.45 (0.48, 0.40)
GENERAL SPECIFICATIONS

Vehicle speed A/C compressor load Engine coolant temperature
Increase: 94°C (201°F) or less
Decrease: 91 °C (196°F) or less
Increase: 95 - 96°C (203 - 205°F)
Decrease: 92 - 94°C (198 - 201°F)
Increase: 97°C (207°F) or more
Decrease: 95°C (203°F) or more
Radiator fan operation Radiator fan operation Radiator fan operation
During acceleration: 19 km/h (12 MPH) or less
During deceleration: 10 km/h (6 MPH) or less
OFF OFF Low-Speed High-Speed
Low Low-Speed Low-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 20 - 69 km/h (12 - 43 MPH)
During deceleration: 11 - 64 km/h (7 - 40 MPH)
OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 70 - 105 km/h (43 - 65 MPH)
During deceleration: 65 - 100 km/h (40 - 62 MPH)
OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 106 km/h (66 MPH) or more
During deceleration: 101 km/h (63 MPH) or more
OFF OFF High-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed