Diagnostic Method
Judge as NG when the continuous time when the following conditions are established is more than 5 seconds.
Judge as OK and clear the NG when the continuous time when the following conditions are not established is more than 5 seconds.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | ≥ 0.018 |
Time Needed for Diagnosis: 5 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.