Diagnostic Method
- Abnormality Judgment
When either of the following conditions are established, it is judged NG.
Judge as OK and clear the NG when the continuous time when all of the following criteria are established is more than the predetermined time (1 s).
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| bus off flag or error warning flag | set |
| ID from body integrated unit is not received. | = 500 milliseconds |
| Data from body integrated unit is not updated. | = 500 milliseconds |
Time Needed for Diagnosis: 1 time
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.